l Home l Lynx Meters l Leopard Meters l Panel Meter Display Colors l Bargraphs.com l Texmate.com l

DL-40H
DL-40H-LR

DL-40H
Leopard Temperature Meter
4 DIGIT 0.56” OR 0.8” LED in a 1/8 DIN CASE

An economical smart temperature meter relay for J, K, R, and T type thermocouples and RTD inputs

Complete Data Sheet
Download PDF 12 Pages 1.2 m
In order to read the PDF, you will need Adobe Acrobat Reader. Its FREE!
General Features
  • Thermocouple (J, K, R and T types) or RTD (Pt-100. 385 and 392 curves. 3 wire/4wire). Digitally Linearized.
  • Optional isolated 16 bit analog output. User or factory scalable to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span from ± one count to the full scale range of – 1999 to 9999 (12000 counts).
  • Auto-sensing AC/DC power supply. For voltages between
    85-265 V AC / 95-370 V DC (PS1) or 18-48 V AC / 10-72 V DC (PS2).
  • Standard red or optional green or super bright red 4-digit LED
  • Red or green 0.8” LED large display option.
  • Four annunciator LEDs provide front panel alarm status indication for up to four setpoints.
  • Two 10 Amp Form C and two 5 Amp Form A relay, or optionally four 5 Amp Form A are available.

Software Features

  • Three-button programming from the front panel (UP, DOWN and PROGRAM buttons).
  • Front panel selectable °C or °F display.
  • Front panel selectable 0.1° or 1° resolution.
  • Front panel selectable display brightness.
  • Four programmable setpoints.
  • Relay activation can be selected to occur above (HI) or below (LO) each setpoint.
  • Hysteresis setting for all four setpoints
  • Four-level brightness control of digital display, and setpoint LEDs.

Input Module Compatibility

LEOPARD FAMILY: Accepts more than 38 different Plug-in I-Series Input Signal Conditioners approved for Texmate’s Leopard Family of meters.

Specifications

  • Input Specs: ...... Depends on Input signal conditioner
  • A/D Converter: ...... 14 bit single slope
  • Accuracy: ...... ±(0.05% of reading + 2 counts)
  • Temp. Coeff.: ...... 100 ppm/°C (Typical)
  • Warm up time: ...... 2 minutes
  • Conversion Rate: ...... 5 conversions per second (Typical)
  • Display: ...... 4 digit 0.56" Red LED display (std), 0.56” or 0.8" Red, Green or Super Bright Red (optn). Range –1999 to 9999 counts.
  • Polarity: ...... Assumed positive. Displays – negative
  • Decimal Selection: ...... Automatic by resolution select XXX•X
  • Positive Overrange: ...... Top segments of digital display flash
  • Negative Overrange: ...... Bottom segment of digital display flash
  • Relay Output: ...... Two 5 A Form A relays and two 10 A Form C, or 5 A form A relays.
  • Analog Output: ...... Isolated 16 bit user scalable mA or V
    AIC (mA out) 4-20 mA @ 0 to 500 ohms max loop resistance
    AIV (volts out) 0-10 V DC @ 500 ohms or higher resistance
  • Power Supply: ...... AC/DC Auto sensing wide range supply
    PS1 (std) 85-265 VAC / 95-370 VDC @ 2.5W max 3.5W
    PS2 18-48 VAC / 10-72 VDC @ 2.5W max 3.5W
  • Operating Temp.: ...... 0 to 60 °C
  • Storage Temp: ...... –20 °C to 70 °C.
  • Relative Humidity: ...... 95% (non condensing)
  • Case Dimensions: ...... 1/8 DIN (Bezel 96Wx48Hmm)
    Depth behind bezel (4.61”) 117 mm Plus (0.57”) 14.5mm for connectors
  • Weight: ...... 6.5 oz., 8.5 oz when packed

l Home l Lynx Meters l Leopard Meters l Panel Meter Display Colors l Bargraphs.com l Texmate.com l

TEXMATE 995 Park Center Drive, Vista, CA. 92083 • 800-839-6283 • www.texmate.com

Copyright © 2000 Texmate Inc. All Rights Reserved.