General Features |
- External transmitters or signal conditioners can be eliminated by directly connecting the sensor to more than 24 Plug-in Input Signal Conditioners that include:
AC Current AC Voltage DC Current
DC Voltage Load Cell Pressure
Process Prototype Resistance
Strain-gage Temperature 4 to 20 mA
- Precalibrated I-Series input modules, that have span or zero potentiometers, can be interchanged between any I-Series compatible meter, without recalibration, because all of the analog scaling and reference circuitry is self-contained within the module.
- 24 V DC excitation is available to power external transmitters and 5 or 10 V DC excitation is available for strain-gages, load cells and resistance bridge type sensors.
- Auto-sensing AC/DC power supply. For voltages between
85-265 V AC / 95-370 V DC (PS1) or 18-36 V AC / 10-60 V DC (PS2).
- Standard red or optional green or super bright red 4 1/2-digit 0.56" LED with display range 19999 to 19999 (40000 counts DX-45).
- Display brightness may be externally controlled.
- Standard red or optional green 4-digit 0.8" LED with display range -9999 to 9999 (20000 counts DX-40).
- Optional NEMA-4X, IP-65 hinged, lockable, water and dust proof cover.
- 1/8 DIN (96 x 48mm ) case easily mounts in thin or thick panels (up to 2). May be ordered with optional extra fire resistant metal case.
Input Module Compatibility |
LYNX FAMILY: Accepts more than 24 different Plug-in I-Series Input Signal Conditioners approved for Texmates Lynx Family of meters.
Specifications |
- Input Specs: ...... Depends on input signal conditioner
- A/D Converter: ...... 16 bit dual slope
- Accuracy: ...... ±(0.05% of reading + 3 counts)
- Temp. Coeff.: ...... 100 ppm/°C (Typical)
- Warm up time: ...... 2 minutes
- Conversion Rate: ...... 3 conversions per second (Typical)
- Display: ...... DX-45 4 1/2 digit 0.56 Red LED display (std) 0.56 Green or Super Bright Red (optn). Range 19999 to 19999 counts.
DX-40 4 digit 0.8 Red LED display (std) 0.8 Green (optn). Range 9999 to 9999 counts.
- Polarity: ...... Assumed positive. Displays negative
- Decimal Selection: ...... Header under face plate
DX-45 XXXXX
DX-40 XXXX
- Positive Overrange: ...... All digits flash.
- Negative Overrange: ...... negative sign and all digits flash
- Power Supply: ...... AC/DC Auto sensing wide range supply
PS1 (std) 85-265 VAC / 95-370 VDC @ 2.5W
PS2 15-48 VAC / 10-72 VDC @ 2.5W
- Operating Temp.: ...... 0 to 60 °C
- Storage Temp: ...... 20 °C to 70 °C.
- Relative Humidity: ...... 95% (non condensing)
- Case Dimensions: ...... 1/8 DIN (Bezel 96Wx48H mm)
Depth behind bezel (4.61) 117 mm
Plus (0.5) 12.7mm for connectors
- Weight: ...... 8 oz., 11 oz when packed.
|